Description

ProCat® Insulation is an unbonded loosefill fiberglas™ thermal insulation. It is designed for use exclusively with theProCat® machine.

Features

  • The ProCat® machine has a “dense mode” setting enable installation of ProCat® insulation at higher R-value in the eaves, where height may be limited
  • Owens Corning® Loosefill Insulation has received the Cradle to Cradle Products Innovation Institute’s Platinum Level Material Health Certificate2

Applications

  • ProCat® Insulation is intended for use in both “open” applications, such as the floor of vented attics, and in “closed cavity” applications, such as walls and floors between stories of a house
  • ProCat® Insulation can be used in both existing and newconstruction

Standards, Code Compliance

  • ProCat® Insulation is manufactured in accordance with ASTM C764
  • ProCat® Insulation is certified by the State of California, Dept. of Consumer Affairs, Bureau of Home Furnishings and Thermal Insulation as meeting the requirements of the California Standards for Insulating Material
  • ProCat® Insulation meets requirements of the State of Minnesota Standards for Insulation Materials and Installation

Design Considerations

To prevent fire or overheating of recessed light fixtures
or similar electrical devices, do not insulate on top of or
within 3 inches of such devices unless they are specifically
approved and labeled “IC rated” (insulation contact).

Do not place insulation in air spaces surrounding metal
flues, chimneys, or fireplaces. Provide minimum clearances
specified in NFPA-31, NFPA-54, or NFPA-211, or as
required by local building codes. 

Installation

Stated R-value is achieved by installing the minimum
required number of bags per 1,000 net sq. ft. at a thickness
not less than the label minimum thickness and minimum sq.
ft. weight. Failure by the installer to provide both the required number of bags and at least the minimum thickness will result in lower insulation R-value.

In order to achieve the R Values stated on this data sheet,
strictly follow Owens Corning’s written instructions and
recommendations for the operation, maintenance and
service of the ProCat® machine.

Fiberglass and Mold

As manufactured, fiberglass insulation is resistant to mold
growth. However, mold growth can occur on building
materials, including insulation, when contaminated with
organic material and when water is present. To avoid mold
growth in fiberglass insulation, remove any water that has
accumulated and eliminate the source of the water as soon
as possible. Insulation that has become wet should be
inspected for residual moisture and organic material. Any
contaminated material should be promptly removed and
replaced. 

ProCat® Insulation is classified by ASTM C764, section 4.1,
as “Type I - Pneumatic application” material. It is considered
noncombustible, per testing in accordance with ASTM E136,
and is permitted for use in all building construction types as
defined in the ICC Intl. Building Code (IBC).

ProCat®

Net Weight 33.5 lbs.
  • R - Value | Bags per 1000 Sq.Ft. | Maximum Net Coverage, Sq. Ft. | Minimum Weight/Sq. Ft. | Minimum Initial Installed Thickness Inches | Minimum Settled Thickness, Inches
  • 13 | 5.1 | 198.0 | 0.169 | 4.75 | 4.75
  • 19 | 7.8 | 128.7 | 0.260 | 7.00 | 7.00
  • 22 | 9.0 | 110.6 | 0.303 | 8.00 | 8.00
  • 26 | 10.7 | 93.5 | 0.358 | 9.25 | 9.25
  • 30 | 12.4 | 80.6 | 0.416 | 10.50 | 10.50
  • 38 | 16.4 | 60.9 | 0.550 | 13.25 | 13.25
  • 44 | 19.1 | 52.3 | 0.641 | 15.00 | 15.00
  • 49 | 21.5 | 46.4 | 0.722 | 16.50 | 16.50
  • 60 | 27.1 | 36.9 | 0.908 | 19.75 | 19.75

ProCat®

Net Weight 33.5 lbs.
  • R - Value | Minimum Bags per 1000 sq. ft | Maximum Coverage Per Bag in Sq. Ft | Minimum Weight in Lb / Sq. Ft. | Minimum Initial Installed Thickness in Inches | Installed Density lb per cubic foot
  • 14 | 11.3 | 90.2 | 0.379 | 3.5 | 1.3
  • 15 | 13.1 | 78.1 | 0.438 | 3.5 | 1.5
  • 22 | 17.8 | 57.4 | 0.596 | 5.5 | 1.3
  • 24 | 24.7 | 41.4 | 0.825 | 5.5 | 1.8

ProCat® Dense

Net Weight 33.5 lbs.
Additional Bags Required per 100 ft of Roof Line
  • | 4:12 | 5:12 | 6:12
  • R - Value | Roof Pitch | Roof Pitch | Roof Pitch
  • 30 | 1.2 | 1 | 0.8
  • 49 | 3.6 | 3 | 2.4
  • 60 | 5.5 | 4.5 | 3.6
Owens Corning does not recommend or approve blending
or adding additional materials or adhesives to this
product during installation. Owens Corning will accept no
responsibility or liability when the product is not installed
in accordance with the product label and installation
instructions.

Owens Corning recommends and provides instructions
for installing ProCat® Insulation from the outside of exterior
sidewalls. You may also install it from the inside, however,
it is important to note that drill and fill installation from the
inside requires a strong working knowledge of construction
and framing principles, texture matching and other variables.
Please consult a professional contractor to perform this job,
if you do not have this expertise.

Technical Data

  • Property (Unit) | Value| Test
  • Thermal resistance | (See coverage charts) | ASTM C518 & ASTM C687
  • Surface Burning Characteristics
  • flame spread / smoke developed | 0 / 0 | ASTM E841
  • flame spread / smoke developed | 0 / 0 | Can/ULC S102.2
  • Critical Radiant Flux (W/cm2) | >0.12 | ASTM E970
  • Combustion characteristics | Noncombustible | ASTM E136
  • Water Vapor Sorption (by weight) | <5% ASTM C1104 / C1104M
  • Odor Emission | Pass | ASTM C1304
  • Corrosion Resistance | Pass | ASTM C665, part 13.8
  • Fungi resistance | Pass | ASTM C1338
1. This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire-hazard or fire-risk assessment of the materials, products, or assemblies under actual fire conditions. However, the results of these tests may be used as elements of a fire risk assessment that takes into account all of the factors pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest five (5) rating.
Pro Cat - Roof Insulator

Certifications and Sustainable Features

  • Certified by SCS Global Services to contain an average of 53% recycled glass content, 31% pre-consumer and 22% post-consumer.
  • Certified to meet indoor air quality standards under the stringent GREENGUARD Indoor Air Quality Certification Program™, and the GREENGUARD Gold Certification.*

Disclaimer of Liability

Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient’s sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of data associated with particular uses of any product described herein. SCS Global Services provides independent verification of recycled content in building materials and verifies recycled content claims made by manufacturers. For more information, visit www.SCSglobalservices.com.

GREENGUARD Certified products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. For more information, visit ul.com/gg. This Home Innovation Research Labs Green Approved mark is your assurance that a product is eligible for points toward National Green Building Certification.
Visit www.GreenApprovedProducts.com for details.
OWENS CORNING INSULATING SYSTEMS, LLC 
ONE OWENS CORNING PARKWAY 
TOLEDO, OHIO, USA 43659
1-800-GET-PINK® 
www.owenscorning.com
Pub. No. 10019483-D. Printed in U.S.A. September 2017.
THE PINK PANTHER™ & © 1964–2017 Metro-Goldwyn-Mayer Studios Inc.
All Rights Reserved. The color PINK is a registered trademark of Owens Corning. © 2017 Owens Corning. All Rights Reserved.
Share by: